Specifications
MODEL
HFT100A
HFT250A
Force capacity
Dynamic(kN)
100
250
Static(kN)
100
250
Load range
2%-100%FS
Testing machine accuracy
Static indication accuracy: ±0.5% Dynamic loading accuracy: ±1%
Actuator dynamic stroke(mm)
150
Displacement measuring range (mm)
0~150(±75)
Displacement measurement resolution(mm)
0.001
Deformation indication relative error
±0.5%
Sine wave test Frequency (Hz)
Standard: 0.01~30;
Optional: 0.01~50HZ; 0.01~100HZ(Static pressure support cylinder)
Max vertical test space(mm)
400~1250
678~1835
Working table height (mm)
800
Effective distance between columns(mm)
533
625
Column diameter(mm)
80
80
Main frame stiffness
3×108
3×108
Machine frame sizes(mm)
990*1000*2550
864*1000*3574
Coaxiality of hydraulic fixture
5%
5%
Power supply
AC 380V± 10%, 50Hz
Sie können mich auch per E-Mail kontaktieren. Meine E-Mail-Adresse ist admin@hssdtest.com